Por favor, use este identificador para citar o enlazar este ítem:
http://repositorio.espe.edu.ec/handle/21000/37721
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.advisor | Velasco Sánchez, Paola Maritza | - |
dc.contributor.advisor | Llanos Proaño, Jacqueline del Rosario | - |
dc.contributor.author | Gallo Tibanquiza, Alberto Enrique | - |
dc.contributor.author | Taco Chuquitarco, Darwin Rodrigo | - |
dc.date.accessioned | 2024-04-15T14:29:10Z | - |
dc.date.available | 2024-04-15T14:29:10Z | - |
dc.date.issued | 2023-12-07 | - |
dc.identifier.citation | Gallo Tibanquiza, Alberto Enrique. Taco Chuquitarco, Darwin Rodrigo (2023). Comparison of Control Strategies for AC-DC Converter for a Wind Energy System with Permanent Magnet Synchronous Generator. Carrera de Ingeniería en Electrónica e Instrumentación. Universidad de las Fuerzas Armadas ESPE. Sede Latacunga. | es_ES |
dc.identifier.other | ENI-0522 | - |
dc.identifier.uri | http://repositorio.espe.edu.ec/handle/21000/37721 | - |
dc.description.abstract | Wind energy contributes to diversifying the energy matrix. These systems can be adapted to various scales, from industrial wind farms to smaller residential systems, makingaccessible and versatile. Furthermore, wind systems promotes environmental preservation by reducing dependence on nonrenewable energy sources like fossil fuels, significantly contributing to climate change mitigation. The challenge posed by wind energy lies in controlling it against disturbances with high variability, such as wind speed. To address this challenge, advanced control systems must be implemented to optimize the performance of wind turbines and minimize the adverse effects of varying wind conditions. This work presents the design and implementation of two control strategies for the AC/DC converter of a wind system with a PMSG generator. First a traditional PI controller is used, followed by a PI+Fuzzy-PI controller. The aim is to analyze and compare the dynamic performance of both control techniques. The results show that the PI+Zuzzy-PI controller has a better dynamic performance than PI controller. The overshoot and settling time can be reduced in the former. Therefore, the effectiveness of PI+Fuzzy - PI controller is evaluated and demonstraed. | es_ES |
dc.description.sponsorship | ESPE-L | es_ES |
dc.language.iso | eng | es_ES |
dc.publisher | Universidad de las Fuerzas Armadas ESPE. ESPEL. Carrera de Ingeniería en Electrónica e Instrumentación. | es_ES |
dc.rights | openAccess | es_ES |
dc.subject | ENERGÍA EÓLICA | es_ES |
dc.subject | CONTROL DIFUSO | es_ES |
dc.subject | AC-DC CONVERTIDOR | es_ES |
dc.title | Comparison of Control Strategies for AC-DC Converter for a Wind Energy System with Permanent Magnet Synchronous Generator. | es_ES |
dc.type | article | es_ES |
Aparece en las colecciones: | Artículos Académicos - Carrera de Ingeniería Electrónica e Instrumentación (ESPEL) |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
AA-ESPEL-ENI-0522.pdf | ARTÍCULO ACADÉMICO | 1,05 MB | Adobe PDF | Visualizar/Abrir |
ESPEL-ENI-0522-P.pdf | PRESENTACIÓN | 1,54 MB | Adobe PDF | Visualizar/Abrir |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.